Description of Controls
 A commercial gas fired Fryer using a fast fry
infra red burner system.
 Available in single model type only.
 This model is fitted with dual main burners and
pilot burners.
 Fitted with single gas controller and
additional flame failure valve to control main
burners and pilots.
 Fryers feature an Over Temperature Safety
Cut Out system with Full Flame Failure Safety
Controls.
 Snap action thermostat sensitive to changes
in oil temperature.
 Open tank design for both units to simplify
cleaning operation.
Part 4 Operation
Operation Guide
1. COBRA Fryers have been designed to provide
simplicity of operation and 100% safety
protection.
2. Improper operation is therefore almost
impossible, however bad operation practices
can reduce the oil / shortening life and produce
a poor quality product. To use this fryer correctly
please read the following sections carefully;
 Filling the Tank.
 Lighting the Pilot Burners.
 Lighting the Main Burners.
 Setting the Operating Temperature.
 Draining and Cleaning.
Single Tank CF4 Controls
C
AUTION
:

This appliance is for professional use and is only to be used by qualified persons.

Only qualified service persons are to carry out installation, servicing or gas conversion
operations.

Components having adjustments protected (e.g. paint sealed) by the manufacturer
should not be adjusted by the user / operator.
Thermostat Control
Knob
'OFF' Button
(Turns 'Off'
Gas Valve
and Pilot).
Pilot Ignition
Button
Flame Failure
Button
Overtemp
Reset Button