230635-2For use in GB & IE Gas Cooktops Models: C6 (600mm) C9 (900mm) INSTALLATION AND OPERATION MANUAL

Pagina 2

8Part 4 OperationOperation Guide 1. Cobra appliances have been designed to provide simplicity of operation and 100% safety protection. 2. Improper

Pagina 3 - C9 Gas Cooktops 900mm Wide

9GriddleThese griddles are fitted with a pilot as a standard option and Flame Failure Protection, which is incorporated by way of a thermo-electric sy

Pagina 4 - Part 1 Introduction

10CORRECT LEVEL FOR FRYING MEDIUM WHEN AT FRYING TEMPERATURE, KEEP TOPPED UP INDICATES CORRECT FRYING MEDIUM LEVEL WHEN COLD After Each Use 1. Clean

Pagina 5 - Gas Supply Requirements

11Trivets and Burners a. Remove the trivets from the top of the appliance, taking note that the trivets are manufactured with a lip on one edge, th

Pagina 6 - Dimensions

12Gas Control Valve Re-Greasing The gas control valve should be dismantled and greased every 6 months to ensure the correct operation of the gas cont

Pagina 7 - Unpacking

13Part 6 Gas ConversionGas Conversion Procedure NOTE:x These conversions should only be carried out by qualified persons. All connections must be c

Pagina 8 - Assembly

14Part 6 Gas ConversionAeration Adjustment1. Check / adjust the main burner aeration gap. This gap should be set to the dimensions shown in the &ap

Pagina 9 - Commissioning

15Part 6 Gas ConversionGas Regulator NOTE:The regulator supplied is convertible between Natural Gas and LP Gas, but it’s outlet pressure is fixed ex

Pagina 10 - Description of Controls

16Part 6 Gas ConversionGas Specifications - Non-UK Only- UK OnlyAppliance Classification Category: II2H3P. Flue Type: A1.NOTE:* The burner operat

Pagina 11

17Replacement Parts List When ordering spare parts, please quote the part number and the description as listed below. If the part required is not lis

Pagina 12 - General

The reproduction or copying of any part of this manual by any means whatsoever is strictly forbidden unless qualified previously in writing by the man

Pagina 13

18 Regulator 228531 Regulator (Natural Gas/LP Gas [Propane] Convertible) ¾” BSP F/F. Gas Conversion Kits - Non UK Only:- UK Only:Part 7 Replacem

Pagina 15 - Gas Conversion Procedure

1ContentsC6 Gas Cooktops 600mm Wide. C9 Gas Cooktops 900mm Wide. Part 1 Introduction ...

Pagina 16

We are confident that you will be delighted with your Cobra Series Cooktop, and it will become a most valued appliance in your commercial kitchen. To

Pagina 17

3NOTE: (*) * - The burner operating pressure is to be measured at the manifold test point with two burnersoperating at full setting. The operating pr

Pagina 18 - Gas Specifications

4Part 2 SpecificationsDimensionsC6 - Gas Cooktop - 600 mm Wide. C6D Model C6C Model C6B Model C9 - Gas Cooktop - 900 mm Wide. C9D Model C9C Mode

Pagina 19 - Open Burners

5Location1. Installation must allow for a sufficient flow of fresh air for the combustion air supply. Combustion Air RequirementsNatural Gas 34 m³

Pagina 20 - Gas Conversion Kits

6The regulator connections are 3/4” BSP female. The connection to the appliance is 3/4” BSP male. (Refer to the 'Specifications' Section for

Pagina 21

7Part 3 InstallationCommissioningThe following commissioning checks must be carried out before the appliance is handed over for use, to ensure that t